RO water filtration system can meet all water source requirements in medical equipment & supplies manufacturing industry.

  • Medical equipment & supplies manufacturing industry requires extremely high water quality and low conductivity because it is related directly to human health. RO water filtration system may meet all water source requirements in the medical equipment & supplies manufacturing industry. 

    Applications of RO water filtration system in the medical industry.

    RO water filtration technology is the most advanced, modern, and popular in developed countries in the world such as USA, Singapore, Korea, and Japan, is applied in many areas including industrial water filtration, residential water filtration, seawater filtration… 

    In the medical industry, water is filtered through RO water filtration system to: 

    • Manufacture pharmacy (dispense oral and injectable drug)  
    • Provide clean water for operating rooms and laboratories…  
    • Wash wounds, medical instruments... 

    How does RO water filtration technology work?

    RO - Reverse Osmosis is a technical membrane (also called a semi-permeable membrane), which only allows selectively clean water to pass by using the pressure of the pump to push water through a semi-permeable membrane, and ions in the form of dissolved mineral salts are trapped on the pressure side of the membrane.

    Requirements of pure water quality depend on various factors such as the membrane size, the membrane hole size, temperature, operating pressure, and surface acreage. The filter levels include pure filtration removing particles from 1 micrometer upwards, ultra-filtration removing particles from 0,2 micrometers, and reverse osmosis removing particles that are greater than 0.0001 micrometers.

    The pump pushing water in the semi-permeable membrane has high pressure, with freshwater is 2-17 bar (30-250 psi), with brackish water is 15.5-26 bar or 1.6-2.6 MPa (from 225 to 375 psi), and with seawater is approximately 55 to 81,5 bar or 6-8 MPa (800-1180 psi). 

    In the pharmaceutical industry, outlet water quality is usually equivalent to distilled water from 1 or 2 times that meets the standard of Vietnam Pharmacopoeia VI.  

    RO water filtration device for medical equipment & supplies manufacturing industry.   

    RO filtration system can change that depends on the water quality (input water source) and the output water quality requirements, using wattage and the actual condition of each installation location.

    The filter membrane of RO demineralization is very sensitive, easy to obstruct, and hard to clean. Because of that, water from the tank has to be treated in the pretreatment stage to ensure the input water of RO system meeting QCVN 02:2009/BYT (National technical regulation on domestic water quality) to protect RO membrane. 

    The water filtration process of the system is often combined the demineralization process with ion exchange technology and reverse osmosis process.

    The filtration system needs to go through the following steps: 

    • Step 1: Impurity treatment: Raw filter column removes organic impurities (iron, lead, manganese…)
    • Step 2: Multi-substances removing: Multi-substances filter column treats iron, manganese, arsenic, and some other dissolved substances.   
    • Step 3: Toxic substances removing: Activated carbon filter column helps to absorb and remove toxic substances in water (pesticides and other toxins have not been previously treated) 
    • Step 4: Soften water: Water softening device helps to remove calcium and magnesium ions in water, prevent RO membrane clogging, protect the membrane. 
    • Step 5: After going through all of the above steps, water is put into transferring tank equipped high-pressure pump to supply water for RO filtration system.  
    • Step 6: RO filter membrane: With extremely small filter core size, RO filter membrane helps to remove all the impurities at a size of 1 micrometer, and only allows clean water molecules to go through. Water flow passes continuously on RO membrane surface, the impurities are washed away by the wastewater stream and the outlet water of the RO membrane is an ultra-pure water source. 

    Conclusion: After being treated by RO water filtration system, the outlet water has high conductivity (about 2 - 5 S/cm). The quality of water is quite low and enough to meet the supply water standard for the treatment stage later.

    The application of two consecutive RO membranes only protects the membranes for each other but cannot improve water quality. To get better water quality and also lower conductivity, RO water filtration system needs to combine with other water filtration technologies such as EDI and UV lights. However, RO system still plays an important role (60%) in the whole system and EDI (40%).   

    The reputable unit supplies RO water filtration system in the market.

    E&C Vietnam Environment Technology Services Joint Stock Company is a reputable contractor in the field of industrial water filtration. We have designed and installed RO water filtration system for many nationwide clinics, hospitals. Our technicians will calculate and check the source water quality before designing, and ensure the system operating effectively, save on costs, operate stably and durably         

    If you would like more consultation on RO water filtration system for medical equipment & supplies manufacturing industry, please directly contact the hotline 0941 113 286 or visit us at the address 

    E&C Vietnam Environment Technology Services Joint Stock Company 

    • Address: Alley 124, Phu Dien Street, Phu Dien Ward, Bac Tu Liem District, Ha Noi City 
    • Phone: 0986.335.848
    • Hotline: 0941.113.286
    • Website: eclim.vn
    • Fanpage:facebook.com/dichvucongnghemoitruong
    • Email: antam@eclim.vn
  • 0.0/ 5

    0 comments

    0
    0
    0
    0
    0
    • Chưa có bình luận nào

RELATED PRODUCTS

0941 113 286